Zitat
c. Pressurize the cooling system by using slow
and steady pump action on the tester pump
handle. Quick or rapid pumps on the tester
handle may cause false readings.
Pressurize the system until the gauge
pressure levels off, between 12-18 psi
(83-124 kPa).


d. The degas cap should release between
12-18 psi (83-124 kPa) allowing the
pressure to level off.

(1) If the degas cap releases with less
than 12 psi (83 kPa), replace the cap.


(2) If degas cap was replaced or held
pressure, apply pressure to 12-18 psi
(83-124kPa) and wait 30 seconds for
pressure to stabilize. If pressure holds,
go to Step 2e. If pressure drops,
continue to next step.


(3) If the gauge pressure drops:

(a) Apply soapy water around the cap
to find any leaks...............
Zitat
c. Druckbeaufschlagung des Kühlsystems mit langsamen
und gleichmäßige Pumpbewegung an der Prüfgerätepumpe
Griff. Schnelles oder schlagartiges Pumpen am Tester
Handle kann zu falschen Messwerten führen.
Das System mit Druck beaufschlagen,bis der Manometerdruck zwischen 12-18 psi abfällt
Druckstufen aus, zwischen 12-18 psi(83-124 kPa).


d. Die Verschlusskappe sollte sich zwischen den folgenden Punkten öffnen
12-18 psi (83-124 kPa), um Druckabbau zu ermöglichen.


(1) Löst sich die Entgasungskappe mit weniger als
als 12 psi (83 kPa), ersetzen Sie die Kappe.

(2) Wenn die Entgasungskappe ersetzt oder gehalten wurde
Druck, Druck auf 12-18 psi anwenden
(83-124kPa) und warten Sie 30 Sekunden für
Druck, sich zu stabilisieren. Wenn der Druck hält,
weiter zu Schritt 2e. Wenn der Druck fällt,
weiter zum nächsten Schritt.

(3) Wenn der Ãœberdruck sinkt:

(a) Seifenlauge um die Kappe herum auftragen.
um eventuelle Lecks zu finden...............................................................................................................


Gruß Juergen