ich kenne das teil nicht, aber ihr habt geprüft, dass diese Ursachen nicht zutreffen Absorption light remains on all the time:
Wrong battery type selection eg. charge gel battery with Calcium-Calcium OR Wettype selection Total battery capacity is too high for dual charging Battery temperature too high Battery is defective A load is connected to battery and chargeris not in power supply mode. und das zutrifft The 3-stage IU0U charge algorithm ensures fast, complete and at the same time gentle charging of the lead acid battery.
Stage 2. THE UO-PHASE . The constant voltage charging, Absorption LED is on . Battery Type Selection : Gel : 14.1V / AGM: 14.3V / Wet : 14.4V / Calcium : 15.5V When the battery voltage rises to the selected Absorption voltage level, the charging switches to Constant voltage charging and battery is over 85% full. The battery is kept at this high voltage while the current reduces gradually to set value at which the charger automatically switches to Float Stage.